Telecom & Off-Grid Infrastructure

Batteries Built for Sites Nobody Visits

48V rack-mount backup for telecom base stations and sealed IP67 packs for solar street lighting. Wide-temperature chemistry, anti-theft engineering, and the tender documentation that infrastructure projects actually require.

-20°C to 60°C Operation    10-Year Design Life    Anti-Theft Enclosures    Tender Documentation Support

48V rack-mount battery backup cabinet supporting a remote telecom tower and solar street lights
Two Product Tracks

One Page, Two Infrastructure Problems

Different form factors, same requirement: unattended operation in harsh environments, purchased in project volume, verified by paperwork.

Track A · Telecom
01 telecom base station backup 800x420 1 - Telecom Solar Street Light Solutions

Telecom Base Station Backup

48V rack-mount LiFePO4 replacing lead-acid strings in BTS cabinets, edge data rooms, and fiber huts. Direct -48V DC plant compatibility.

48V / 51.2V · 50–200Ah · SNMP / RS485 · 16× Parallel

Track B · Street Light
02 solar street light packs 800x420 1 - Telecom Solar Street Light Solutions

Solar Street Light Packs

Compact sealed 12.8V/25.6V packs for all-in-one and split solar street lights — pole-mount, buried, or integrated into the fixture head.

12.8V / 25.6V · 20–100Ah · IP67 · PV Direct

Model Lineup

Standard Infrastructure Series

Track A — Telecom Rack Series
ModelVoltageCapacityForm FactorCommsDesign LifeTypical Runtime*
SC-TB48-5051.2V50Ah19" 3U rackRS485 / CAN10 years2–4h @ 1kW
SC-TB48-10051.2V100Ah19" 3U rackRS485 / SNMP10 years4–8h @ 1kW
SC-TB48-20051.2V200Ah19" 4U rackRS485 / SNMP / dry contact10 years8–16h @ 1kW
Track B — Solar Street Light Series
ModelVoltageCapacityEnclosureInstall TypeAutonomy**Temp Range
SC-SL12-2012.8V20AhIP67 sealedIn-fixture / pole-top3 nights-20°C to 60°C
SC-SL12-5012.8V50AhIP67 sealedPole-mount box4 nights-20°C to 60°C
SC-SL24-6025.6V60AhIP67 sealedPole-mount / buried5 nights-20°C to 60°C
SC-SL12-10012.8V100AhIP67 + anti-theft bolt kitBuried5 nights-20°C to 60°C

※ *Runtime depends on site load. **Autonomy calculated at 30W LED / 10h nightly duty. Custom capacities, connectors, and enclosure branding available at project volume.

Engineering for Unattended Sites

Designed Around Three Field Realities

Infrastructure batteries fail for reasons that never show up in a datasheet: heat, theft, and the truck-roll cost of a site visit. We design against all three.

🌡️

Wide-Temperature Chemistry

Cell selection and BMS thermal derating tuned for 60°C cabinet interiors and -20°C mountain sites — the environments where standard packs quietly lose half their life.

🔒

Anti-Theft by Design

Keyed steel enclosures, tamper alarms via dry contact, optional GPS modules, and cell formats with minimal resale value — because in many markets, theft kills more batteries than cycling does.

📉

Zero Truck-Roll Monitoring

SNMP and RS485 telemetry surfaces SOC, SOH, and fault codes to your NOC. Predict failures from the office instead of discovering them at the site.

🔋

Deep-Cycle Float Hybrid

Unlike lead-acid, the same pack handles daily cycling in unstable-grid regions and long float in stable ones — one SKU across your whole territory.

📦

Project Logistics

UN38.3-certified packaging, palletized sea freight, and staggered delivery schedules matched to tender installation timelines.

🛠️

10-Year Design Life

6,000+ cycles at 90% DoD, translating to 10+ years in float-dominant telecom duty — matched with warranty terms tender committees accept.

Built to Win Tenders, Not Just Orders

Government and carrier procurement is won on documentation completeness before price is ever discussed. Every project quote ships with a full tender support package:

Project Pricing Tiers

Project Buyer FAQ

What Tender & Carrier Buyers Ask Us

No — and any supplier who says yes is creating a warranty problem for you. Our packs replace full strings, and our BMS float voltage is configurable to match your existing -48V rectifier settings so the rectifier plant itself needs no changes.

Battery only, by design — we are the battery OEM behind street light brands and EPC contractors, not their competitor. We match our pack’s charge profile and connector to your fixture and controller of choice, and can ship direct to your assembly partner in China to save a freight leg.

Advance-replacement RMA for project customers: we ship the replacement unit on fault confirmation via telemetry data or photos — no requirement to return the failed unit before the new one ships. Failed units are collected in batches at your regional depot.

Yes. Multi-phase tenders typically install in geographic batches; we schedule production and shipping against your installation calendar, with FAT reports per batch. Framework agreements lock pricing across all phases.

Street light packs: 100 units for label and enclosure branding. Telecom racks: 50 units. Custom firmware, connectors, or enclosure dimensions: quoted per project, usually from 200 units.

Quoting an Infrastructure Project?

Send us your tender spec table or site requirements. We return a compliant technical response with tiered project pricing within 48 hours.

48-Hour Tender Response    SGS / TÜV Inspection Support    Advance-Replacement RMA    Framework Agreements Available

Get a Custom Quote in 24 Hours !

Engineers respond within 1 business day.

Inquiry Form